AES Cabinets &
SOLIS 30 - 150kW
Inverter Integration
High-Voltage Storage Made Easy for Commercial and Industrial Projects
High-Voltage Storage Made Easy for Commercial and Industrial Projects


The nominal voltages of the CAB-106 (332 VDC), CAB-160 (499 VDC), CAB-210 (665 VDC), and CAB-266 (832 VDC) align with Solis’s 150–950 VDC battery range.
Connect directly to both Solis battery ports using the cabinet’s internal fused DC distribution.
LYNK II Gateway (required accessory) enables real-time CANBus communication with Solis BMS1/BMS2.
Supports black start, event logging, SoC reporting, and full inverter coordination.
| Cabinet | Nominal Energy Capacity | Usable Energy Capacity | Battery Max. Continuous Power | System Nominal Voltage | Charging Voltage Range | Voltage Limits | Nominal Cell Capacity | Usable Cell Capacity | Max. Continuous Current |
|---|---|---|---|---|---|---|---|---|---|
| AES 106HV / CAB-106 | 106kWh | 104kWh | 52kW | 332.8V | 310 - 360V | 292 - 369V | 320Ah | 314Ah | 157 A (C/2) |
| AES 160HV / CAB-160 | 160kWh | 157kWh | 79kW | 499.2V | 465 - 540V | 437 - 553V | |||
| AES 210HV / CAB-210 | 212kWh | 209kWh | 104kW | 665.6V | 620 - 720V | 583 - 738V | |||
| AES 266HV / CAB-266 | 266kWh | 261kWh | 131kW | 832V | 775 - 900V | 728 - 923V |

| Solis Inverters | Configuration (Inverter : Cabinet) | CAB-106 | CAB-160 | CAB-210 |
|---|---|---|---|---|
| AC Output / Usable Storage / Estimated Runtime | ||||
| 30K (208V) | 1 : 1 | 30kW | 104kWh | 3.5HR | 30kW | 157 kWh | 5HR | 30kW | 209kWh | 7HR |
| 30K (480V) | 1 : 1 | 30kW | 104kWh | 3HR | 30kW | 157kWh | 5HR | 30kW | 209kWh | 7HR |
* Battery limited.


| Solis Inverters | Configuration (Inverter : Cabinet) | CAB-106 | CAB-160 | CAB-210 |
|---|---|---|---|---|
| AC Output / Usable Storage / Estimated Runtime | ||||
| 40K (480V) | 1 : 1 | 40kW | 104kWh | 2.5HR | 40kW | 157 kWh | 4HR | 40kW | 209kWh | 5HR |
| 1 : 2 | 40kW | 208kWh | 5HR | 40kW | 314kWh | 7.5HR | 40kW | 418kWh | 10.5HR | |
| 50K (480V) | 1 : 1 | 50kW | 104kWh | 2HR | 50kW | 157 kWh | 3HR | 50kW | 209kWh | 4HR |
| 1 : 2 | 50kW | 208kWh | 4HR | 50kW | 314kWh | 6HR | 50kW | 418kWh | 8HR | |
| 60K (480V) | 1 : 1 | Up to 52kW* | 104kWh | 2HR | 60kW | 157 kWh | 2.5HR | 60kW | 209kWh | 3.5HR |
| 1 : 2 | 60kW | 208kWh | 3.5HR | 60kW | 314kWh | 5HR | 60kW | 418kWh | 7HR | |
* Battery limited.


| Solis Inverters | Configuration (Inverter : Cabinet) | CAB-210 | CAB-266 |
|---|---|---|---|
| AC Output / Usable Storage / Estimated Runtime | |||
| 75K (208V) | 1 : 1 | 75kW | 209 kWh | 2.8HR | 75kW | 261kWh | 3.5HR |
| 1 : 2 | 75kW | 418kWh | 5.6HR | 75kW | 522kWh | 7HR | |
* Battery limited.


| Solis Inverters | Configuration (Inverter : Cabinet) | CAB-210 | CAB-266 |
|---|---|---|---|
| AC Output / Usable Storage / Estimated Runtime | |||
| 100K (480V) | 1 : 1 | 100kW | 209 kWh | 2HR | 100kW | 261kWh | 2.6HR |
| 1 : 2 | 100kW | 418kWh | 4HR | 100kW | 522kWh | 5.25HR | |
| 125K (480V) | 1 : 1 | 125kW | 209 kWh | 3HR | 125kW | 261kWh | 2HR |
| 1 : 2 | 125kW | 418kWh | 6HR | 125kW | 522kWh | 4HR | |
| 150K (480V) | 1 : 1 | *100kW | 209 kWh | 2.5HR | *130kW | 261kWh | 2HR |
| 1 : 2 | 150kW | 418kWh | 5HR | 150kW | 522kWh | 3.5HR | |
* Battery limited.
Whether your site is wired for 120/208V or 277/480V three-phase service, Solis has a model ready, and the AES Cabinets are compatible with both:
Each cabinet ships with a preconfigured LYNK II Gateway for:
![]()
Closed-loop CANBus communication with Solis inverters.
![]()
Monitoring of battery SoC, temperature, voltage, current.
![]()
Event logging and safe fault isolation.
![]()
Access via LYNK ACCESS (local) or LYNK CLOUD (remote monitoring).

This isn’t a science project. With Discover + Solis, commercial energy storage is simple:
1. Choose your inverter(s).
2. Add 1 or 2 AES 210HV cabinets per inverter.
3. Use the included cables and LYNK II Gateway.
4. Power up. You are live.
Our team is available to support system design for advanced microgrids, cogeneration, or export-controlled systems.